Height Extension Studs (4) per pack
Part Number L (in.) A B  
10.002 .39 M4 M4  
  15.002 .59 M4 M4  
  20.002 .79 M4 M4  
  25.002 .98 M4 M4  
  30.002 1.18 M4 M4  
  60.002 2.36 M4 M4  
  65.002 2.55 M4 M4  
  97.002 3.81 M4 M4  
Back plate stand-off studs 0.25"
No Photo 40600.099 (4) per pack
Louver Plate - Fits one ventilation opening
70000.261 (VL)

Package includes 2 grids and 4 rivets
Color: Beige
Standard cutout 5"x5"

Document pocket- DIN A4 - Self-adhesive
1021.020 (PPS)
1031.010(PPD)

8.27 x 5.12 x .50
9.00 x 8.50 x 1.00
Color: Beige

Carrying Handle
41270.070 (CH)

Height 1.97 Color: Black, Width reinforcementrib + screws
Made of Vyncolite

Air vents

Two air vents must be mounted per enclosure sufficient air circulation and prevent condensationComplete with template and screws. Air vents are preferably mounted in the upper and lower part of the base.

10000.010 (MEDV) Set of 2 pieces in polyamide  Color: Grey
SEDV Small drain vent set of 2 pieces in polyamide  Color: Grey
Keys
70000.356

For safety-lock No. V2432E

70000.450 For safety lock with .31" square (8 mm)
70000.451 For safety lock with .31" triangle (8 mm)
70156.105 For safety lock with .43" triangle (11 mm)
70000.452 For safety lock with double bit yale .12" (3 mm)
No Photo L/034191.009 Insulated spanner M20 (1000V)
Latches
VJLL Optional twist latch
VJPL Standard padlockable latch (316 stainless steel)
VJTPL Optional twist padlockable latch
Surface-Mounted Windows
No Photo SW32 Detailed drawings available upon request.
No Photo SW44 Detailed drawings available upon request.
No Photo SW64 Detailed drawings available upon request.
No Photo 95HCD Hinged, with gasket IP55 - Detailed drawings available upon request.
SW84N Screw IP67, with indication strip
SW84X

Screw IP67, without indication strip
UL listed when factory installed
Detailed drawings available upon request.

SW97

Screw-on IP67
UL listed when factory installed on any enclosure
Detailed drawings available upon reques
t.

 
 
HP45 Series Semiconductor Control Panel Heater

Features:
-Designed to protect electronic, pneumatic, hydraulic and mechanical equipment requiring protection from low temperatures, condensation and corrosion. The PTC heater unit will maintain a stable temperature environment within enclosures, allowing critical components to perform with consistent reliability for longer periods.
Installation:
-Mount unit at or near the bottom of the cabinet. Improved heat dissipation will be achieved by using two or more smaller heaters wired in parallel. If a technical requirement exists for a specific temperature, regardless of the external ambient temperature, a temperature regulator can be installed. It is recommended 2-3" spacing.
Caution:
-Do not mount on wooden structures.
-Avoid placement near heat-sensitive components

 
HP45 - Technical Data
Voltage:

AC 110-120 V

Heating Power: see below
Heating Element: PTC (Positive Temperature Coefficient) self regulating and temperature limiting
Heating Body: Anodized extruded aluminum
Connection: SJT 3 x 18 AWG Length 20"
Mounting: clip mounting for 1. 375" rails
Protection Class: I (test voltage: 1250 V)
Protection: IP 54

Approval:

UL recognized

Article No. Heating Power
at 68° F
Surface Temp.
(approx.)
Starting Current
(approx.)
Dimensions
(H x W x D)
Weight
lbs.
HP45-15 15W 149°F 0.6A 2.6 x 2.8 x 2" 0.66
HP45-30 30W 167°F 1.2A 2.6 x 2.8 x 2" 0.66
HP45-50 50W 194°F 1.5A 5.5 x 2.8 x 2" 1.10
HP45-80 80W 203°F 2.0A 8.7 x 2.8 x 2" 1.76
HP45-100 100W 212°F 3.0A 8.7 x 2.8 x 2" 1.76
 

The diagram represents a painted, non-insulated fiberglass enclosure mounted in a calm air, building interior. The lowest temperature differential between room temperature and cabinet interior must be 5 K + to prevent humidity and condensation. For outdoor applications, double the heating power requirement.

 

PH = Power required installed (W)
PV = Existing power from components (W)
T = Temperature differential (Kelvin) ambient to cabinet interior
A = F ree-standing switch cabinet area (SQ. FT. )
k = Heat transmission coefficient (W/ SQ. FT. K) convection in quiet air:
      Plastic approx. 0. 28W/ SQ. FT. K
      Printed steel approx. 0. 51W/ SQ. FT. K
      Aluminum approx. 1. 85W/ SQ. FT. K

Example : PH = T x k x A
                PH = 5K x 0. 28W/ SQ. FT. K x 50 SQ. FT. =70W
Formula with Solution: PV = Existing power from components (W)
               PH = T x k x A - P V

 
 
HF Series Heater Fan

HF250
HF400

Features:
-Heater-blower with axial fan for ideally forced air circulation
-Compact design
-Quick-clip mounting
-Long service life
-Maintenance free
-Compact heating fan, prevents accumulation of condensation
and ensures an even temperature in switch cabinets.
Applications:
Control panels, Free-standing cabinets, Telecommunication base stations, Cabins, ATM's, Parking control systems

 
HF Technical Data
Voltage: AC 110-120 V, 50-60 Hz
Heating Power: see table
Circulation Power: 1,236 ft 3/h (35 m 3 /h) free blowing
Axial Fan: Ball bearing Life expectancy: 30,000 hrs. at 68° F (20° C) ambient temperature
Heating Element: Micanite with fail-safe thermostat
Heating Body: Anodized, extruded aluminum in black color
Connection: 3-pole terminal for AWG 12
Mounting: Clip mounting for 1.375" rails (35 mm DIN)
Protection Class: I
Protection: IP 20
Approvals: UL and C-UL (recognized)
           
  HF250 HF400      
Heating Power 250W 400W      
Surface Temp. (max.) 167° F (75° C) 167° F (75° C)      
Current (approx.) 2.2A 3.5A      
Dimensions (inches) 3.15 x 3.15 x 7 3.15 x 3.15 x 9.76      
Weight (lb.) 2.1 2.9      
 
 
HA Series Heater Attachment

Features:
-Flat heater surface combined with an axial fan produces optimum forced convection of hot air.
-The heating attachment in combination with the axial fan ensures an optimum heat distribution. In case of fan breakdown, overheating will be prevented by a failsafe thermostat.
-Temperature-limiting
-Compact design
Applications:
Control panels, Telecommunication base stations, Free-standing cabinets, Cabins, ATM's, Parking control systems

 
HA Technical Data
  HA200-115 HA200 -230  
Voltage: AC 115 V, 50-60 Hz AC 230 V, 50-60 Hz  
Heating Power: 200 W 200 W  
Current: 1.75 A 0.9A  
Heating Body: Anodized extruded aluminum Anodized extruded aluminum  
Dimensions: 6.3 x 4.7 x 1" 6.3 x 4.7 x 1"  
Connection: 3-pole terminal for AWG 15 (1.5 mm.²) 3-pole terminal for AWG 15 (1.5 mm²)  
Weight: 1.1 lb. 1.1 lb.  
Protection: IP 54 IP 54  

Approvals:

UL (recognized) UL (recognized)  

Note: Other power ranges available upon request           Designed for axial fan sizes 4.69 x 4.69"

 
 
VES Series Small Thermostat

VESNC
VESNO

Features:
-Easy installation
-Wide adjustment range
-Small dimensions
-Thermostat NC for the control of heaters/ Thermostat NO for the control of filter ventilators, or for switching signal transmitters in the case of overheating.
Applications:
Air temperature control and monitoring, in switch-gear cabinets, Heaters, filter ventilators, heat exchangers, signal transmitters

VES Technical Data
Sensor element: thermostatic bi-metal
Adjustment range: 30 -140° F, switching diff e rence approx. 4 K
Contact type: NC (normally closed), quick-acting contact; NO (normally open), quick-acting contact
Switching capacity: NC: 15 A (1) AC 120 V; NO: 15 A (1) AC 120 V
Noise suppression: "N" (acc. to VDE 0875)
Dimensions: 2.4 x 1.3 x 1.4"
Connections: 2-pole terminal for AWG 14 (0.04 in 2)
Mounting: clip mounting for 1.375" rails (35 mm DIN)
Housing: plastic UL 94 VO
Protection: IP 30
Weight: 1.27 oz.
Approval: UL and C-UL (recognized)
 
 
MFR -012 Series  Humidity Control

MFR -012

Features:
-Designed for the control of heaters to increase the dew point at critical humidities of 65% RH or higher. This will retard condensation; thus preventing corrosion and greatly extending the life expectancy of components.
Applications:
Control panels and enclosures, ATM machines, Tool cabinets Control systems, Indicator panels

MFR -012 Technical Data
Adjustment range: 35 -100% RH
Tolerance: + 3% RH
Hysteresis: approx. 4% RH (at 50% RH)
Permittable temperature : 32 -140° F (0-60° C)
Type of contact: change -over
Maximum switching capacity: AC 230 V/ change -over5 A (resistive load); AC 230 V/ 0.2 A (inductive load); DC 50 V/ 1A (inductive load)
Minimum load: AC/ DC 20 V . 100 mA
Service life/ Life expectancy: 50,000 cycles (at AC 230 V / 5 A)
Sensing element: synthetic fibers
Protection: IP 20
Noise suppression: "N" (acc. to VDE 0875)
Connections: 4-pole terminal, 2. 5 mm²
Mounting: clip mounting for 1.375" rails (35 mm DIN Rails) (EN50022)
Dimensions: 2.64" x 1.97" x 1.5"
Housing: plastic UL 94 VO
Weight: 0. 22 lb. (0. 1 kg)
Approval: UL (pending)
 
 
PCP Series Pressure Compensation Plug

PCP

Features:
-In tightly closed control panels, no pressure compensation can take place at temperature variations (e. g. day/ night operation). This involves the risk, that, due to the depression, dust and humidity is absorbed into the control panel.
-Easy installation
-High efficiency
-Especially designed to permit a controlled pressure compensation. High protection type of the pressure compensation plug (IP 45), does not affect the protection type of the control panels.

PCP Technical Data
Dimensions: 2. 6" diameter x 1.2"
Mounting: PG 29 thread with union nut
Material: polycarbonate / ABS
Housing color: grey
Air intake housing: approx. 2.8 in²
Protection: IP 45
 
 
ETHC Series Electronic Humidity and Temperature Controller

ETHC -115
ETHC -230

Features:
-Electronic temperature controller and humidity controller for the independent detection of relative humidity and temperature.
-Temperature and humidity are independently adjustable
-High-switching capacity
-Optical indication of function
-The electronic temperature controller and hygrostat detects the set temperature and humidity of the ambient air, switching resistive and inductive loads (e. g. heating or cooling appliances).

 ETHC Technical Data
Temperature range: 32 -140° F (0-60° C)
Hysteresis: approximately 2K
Humidity range: 50-90% relative humidity, adjustable
Response time: approximately 160 seconds
Connected voltage: 115 V/ 50-60 Hz
Relay output: change-over contact
AC 8 A (4) 115 V; DC 0,5 A/ 100 V; DC 8 A/ 12 V, DC 5 A/ 35 V
Service life: 105 cycles
Optical indication of function: LED
Mounting: clip mounting for 35 mm DIN and EN50022 rails
Housing: plastic UL 94VO
Dimensions: 2 x 2.65 x 1.7"
Weight: 0.3 lb.
Protection: IP 30
Approvals: UL (pending)

 

We have attempted to present the information about our vendor's products on this website in a straight-forward manner. We offer this information as accurate at the time of publication. Specifications are subject to change without notice. Electro-Stock, Inc. is not responsible for inadvertent errors.

About UsFAQServicesTerms & ConditionsPolicies

Since 1983   

Hours: Monday through Friday 8:30am through 4:00pm CST - Leave Messages On Voice Mail After Hours.
Phone: 630-682-1542  Fax: 630-682-1562             Order Line: 800-876-1152 (USA Only, Not Illinois)

Email: sales@electrostock.com         Mail & Remit To: 1218 E. Wilson Ave. Wheaton, IL 60187
USA

 Home | contact | © 1996 - 2008 Electro-Stock, Inc | Original Design by www.mitchinson.net | Licensed under a Creative Commons Attribution 3.0 License