you are here > Lines Carried > Mega Electronics > Cordage > European

Mega Electronics, Inc.  European Cordage

 

European Cordage

Cordage can be cut, stripped and terminated to meet your specific requirements. ROHS Compliant. For more information, please call with your inquiries.

H05VVF European Cable

H05VV-F cable is suitable for light moving services such as the connection of small domestic appliances, television, washing machines, refridgerators, etc.

It is not recommended to use it exposed to the elements, in industrial or agricultural workshops or for powering non-domestic portable tools. It is not designed to be laid underground.

PVC insulation type T12. The standard identification is the following:

  • 1 cond: black
  • 2 cond: blue-brown
  • 3 cond: blue-brown-green/yellow
  • 4 cond: gray-brown-black-green/yellow

Other identifications possible upon request. H03VVF, H03VVH2 and H05RRF available upon request.

  • Maximum Service Temperature: 70°C
  • Minimum Service Temperature: 5°C
  • Maximum Short-Circuit Temperature: 150°C
  • Nominal Voltage: 300/500V
  • Additional Cordage Available Upon Request

 

Part No. n° x Cross Section
(mm²)
Current Capacity
(A)
Conductor Resistance
ohms/km20C
Approx. Dim.
O.D.
Approx. Weight
kg/km
131601103 2 0.75 6 26 6.5 50
131601102 3 0.75 6 26 6.7 69
131601126 4 0.75 6 26 7.6 77
131601104 5 0.75 6 26 8.6 105
131601106 2 1 10 19.5 6.8 61
131601109 3 1 10 19.5 7.05 79
131601119 4 1 10 19.5 8.15 102
131601129 5 1 10 19.5 9.4 120
131601114 2 1.5 16 13.3 7.8 90
131601111 3 1.5 16 13.3 8.25 115
131601116 4 1.5 16 13.3 9.6 165
131601123 5 1.5 16 13.3 10.6 190
131601121 2 2.5 25 7.98 9.25 135
131601125 3 2.5 25 7.98 10.2 171
131601135 4 2.5 25 7.98 11.3 212

Return to top

H07RNF European Cable

H07RN-F cable is suitable for dry damp, wet locations, exposed to the elements or in workshops with an explosive atmosphere. It is designed to withstand average mechanical stress, for example for machines in industrial and agricultural workshops, large boilers, heating plates, hand lamps, electric tools such as drills, circular saws, domestic appliances, motors and transportable machines on construction sites and agricultural exploitations, etc.

The use of up to 1kV in alternating or direct current is accepted in fixed protection assemblies (in tubes or machines) and for connections of motors of lifting devices and similar machines.

Thermosetting rubber EI4 type insulation. The standard identification is the following:

  • 1 cond: black
  • 2 cond: blue-brown
  • 3 cond: blue-brown-green/yellow
  • 4 cond: gray-brown-black-green/yellow
  • 5 cond: blue-gray-brown-black-green/yellow
  • 6 or more: black numbered-green/yellow

Other identifications possible upon request. H05RNF available upon request.

  • Maximum Service Temperature: 60°C
  • Minimum Service Temperature: -25°C
  • Maximum Short-Circuit Temperature: 200°C
  • Nominal Voltage: 450/750 V
  • From 1 to 36 Conductors
  • Up to 110A Current Capacity
  • Please call for details on cables not shown below

 

Part No. n° x Cross Section
(mm²)
Current Capacity
(A)
Voltage Drop
(V/A km)
Approx. Dim.
O.D.
Approx. Weight
kg/km
131600001 2 1 10 45.2 8.3 92
131600002 2 1.5 16 30.9 9.2 117
131600003 2 2.5 25 18.5 11.0 170
131600004 2 4 34 11.5 12.6 233
131600005 2 6 43 7.66 14.0 303
131600006 2 10 60 4.43 19.0 551
131600007 2 16 79 2.81 21.4 737
131600117 3 1 10 39.2 8.9 111
131600103 3 1.5 16 26.7 9.7 141
131600118 3 2.5 20 16.0 11.8 206
131600119 3 4 29 9.95 13.5 285
131600120 3 6 36 6.63 15.0 373
131600121 3 10 51 3.84 20.4 679
131600122 3 16 67 2.43 22.9 929
131600133 3 25 89 1.57 26.7 1321
131600134 3 35 110 1.11 30.3 1756
131600135 4 1 10 39.2 10.0 139
131600123 4 1.5 16 26.7 10.9 173
131600105 4 2.5 20 16.0 13.0 253
131600106 4 4 30 9.95 14.8 349
131600107 4 6 37 6.63 16.7 468
131600108 4 10 52 3.84 22.2 828
131600110 4 16 69 2.43 25.0 1144
131600112 4 25 92 1.57 29.9 1673
131600114 4 35 114 1.11 33.6 2192
131600115 4 50 143 0.776 39.0 3025
131600116 4 70 178 0.546 43.9 4024
131600128 4 95 210 0.414 50.4 5255
131600132 5 1 10 39.2 11.0 169
131600104 5 1.5 16 26.7 11.6 205
131600129 5 2.5 20 16.0 14.3 306
131600130 5 4 30 9.95 16.6 433
131600131 5 6 38 6.63 18.5 575
131600109 5 10 54 3.84 24.5 1007
131600111 5 16 71 2.43 27.8 1402
131600113 5 25 94 1.57 32.6 2049
Return to top
M-RZ1-K Halogen Free Fire Retardant Power Cable

 This cable with zero halogens is a high security cable. In case of fire, it does not emit toxic or corrosive gases, thereby protecting public health and avoiding any possible damage to electronic equipment. For this reason, its use is recommended in public places such as: hospitals, schools, museums, airports, bus terminals, shops in general, tunnels, the underground, etc., as well as in calculation centres, offices, production plants, laboratories, etc..
1.- Does not emit toxic substances: The gases and acids emitted by the combustion of a cable containing halogens are highly toxic for the people exposed to these gases, possibly resulting in death due to poisoning. The M-RZ1-K (AS) cable does not emit any of these substances, thereby considerably improving the overall safety of the installation.
2.- Does not emit corrosive substances: The hydrochloric acid (HC1) given off by the combustion of a cable containing halogens is highly corrosive and seriously affects electronic and computer equipment. The M-RZ1-K (AS) does not emit hydrochloric acid (HC1), thereby avoiding this type of damage.
3.- Low smoke emission: This cable avoids loss of visibility due to smoke produced by cable combustion, thereby making the evacuation of people and the performance of rescue personnel easier.
4.- Great power: The cross linked polyethylene insulation (XLPE) allows greater power transmission as well as a higher resistance to overloads. Additionally, it raises the maximum conductor temperature to 90º C (vs. 70º C in type NYY or VV cables).
5.- Fire proof properties: The no fire propagation properties of the M-RZ1-K (AS) cable contributes towards improving the overall safety of the installation.
6.- Ecological: The M-RZ1-K (AS) cable does not contain any halogenated materials, thereby avoiding dioxin emissions into the atmosphere.
The standard color code is the following:
* 1 cond: black
* 2 cond: blue-brown
* 3 cond: blue-brown-green/yellow
* 4 cond: gray-brown-black-green/yellow
* 5 cond: blue-gray-brown-black-green/yellow
* 6 or more: black numbered-green/yellow

Part No. Number of Conductors Cross Section
(mm²)
Current Capacity
(A)
-- Approx. Dim.
O.D.
Approx. Weight
kg/km
13HF2x1.5 2 1.5 26   8.3 97
13HF2x2.5 2 2.5 36   97 -
13HF2x4.0 2 4 49   11.0 206
13HF2x6.0 2 6 63   11.1 217
13HF2x10.0 2 10 86   13.0 323
13HF3G1.5 3 1.5 26   9.0 116
13HF3G2.5 3 2.5 36   9.8 151
13HF3G4.0 3 4 49   11.0 206
13HF3G6.0 3 6 63   11.9 269
13HF3G10.0 3 10 86   14.1 412
13HF4G1.5 4 1.5 23   9.7 136
13HF4G2.5 4 2.5 32   10.8 184
18HF4G4.0 4 4 42   12.0 252
13HF4G6.0 4 6 54   13.2 334
13HF4G10.0 4 10 75   15.4 513
13HF5G1.5 5 1.5 23   10.3 159
13HF5G2.5 5 2.5 32   11.6 217
13HF5G4.0 5 4 42   13.0 302
13HF5G6.0 5 6 54   14.4 404
13HF5G10.0 5 10 75   16.9 627
Return to top

 

We have attempted to present the information about our vendor's products on this website in a straight-forward manner. We offer this information as accurate at the time of publication. Specifications are subject to change without notice. Electro-Stock, Inc. is not responsible for inadvertent errors.

About UsFAQServicesTerms & ConditionsPolicies

Since 1983   

Hours: Monday through Friday 8:30am through 4:00pm CST - Leave Messages On Voice Mail After Hours.
Phone: 630-682-1542 
        
Order Line: 800-876-1152 (USA Only, Not Illinois)

Email: sales@electrostock.com         Mail & Remit To: 1218 E. Wilson Ave. Wheaton, IL 6018
9-6748 USA

 Home | Contact | © 1996 - 2012 Electro-Stock, Inc | Original Design by www.mitchinson.net